QR – SINGLE PHASE RESIN FILLED LINE INDUCTOR

For harmonic filtering. Line voltage 220 – 260 V.
Series: QR
Single phase resin filled line inductor
If you need more information you can contact us at sales@comlec.com
  • Line inductor for harmonic filtering
  • For different values of current and inductance or other applications, please consult
  • The ultimate inductor design
  • Advantages of using resin:
    • Protection against corrosive environments
    • Suitable for elevated vibration levels
    • No damage of wire isolation due to current peaks
    • Reduction of noise and internal vibrations

PRODUCTS IN THIS FAMILY

Reference Description In (A) Motor rating L (mH)
QR2.5 single phase resin filled line reactor 2,5 A 0,23 kW / 0,31 CV 8,785
QR4 single phase resin filled line reactor 4 A 0,38 kW / 0,5 CV 5,491
QR5 single phase resin filled line reactor 5 A 0,46 kW / 0,6 CV 4,393
QR6.3 single phase resin filled line reactor 6,3 A 0,55 kW / 0,75 CV 3,486
QR8 single phase resin filled line reactor 8 A 0,75 kW / 1 CV 2,745
QR10 single phase resin filled line reactor 10 A 1,1 kW / 1,5 CV 2,196
QR12.5 single phase resin filled line reactor 12,5 A 1,5 kW / 2 CV 1,757
QR16 single phase resin filled line reactor 16 A 1,85 kW / 2,5 CV 1,373
QR20 single phase resin filled line reactor 20 A 2,2 kW / 3 CV 1,098
QR25 single phase resin filled line reactor 25 A 3 kW / 4 CV 0,879
QR31.5 single phase resin filled line reactor 31,5 A 4 kW / 5,5 CV 0,697

DIMENSIONS AND WEIGHTS

Reference In (A) Dimensions mm Weight kg Fig
A B C D E Ø
QR2.5 2,5 A 84 101 98 88 55 5 0.77
QR4 4 A 84 101 98 88 55 5 0.77
QR5 5 A 84 101 98 88 55 5 0.94
QR6.3 6,3 A 106 123 118 110 74 5 1.4
QR8 8 A 106 123 118 110 74 5 1.4
QR10 10 A 106 123 118 110 74 5 1.4
QR12.5 12,5 A 106 123 118 110 74 5 1.4
QR16 16 A 106 123 118 110 74 5 1.9
QR20 20 A 118 138 131 121 88 6 3.2
QR25 25 A 118 138 131 121 88 6 3.2
QR31.5 31,5 A 136 162 156 145 104 6 3.2

TECHNICAL CHARACTERISTICS

Isolation Class B – 130º C
Winding Class HC – 200ºC
Cover Polymer of latest technology, non-flammable V-0 according to UL94
Frequency 50-60 Hz
Protection degree IP-20
Includes Thermal protection against over temperature
Mounting Din Rail mounting (for ratings up to 5 A)
By screws (for all ratings)
Standards IEC/EN/UNE-EN 60076-6, CE
Line voltage 220 – 260 V
Test voltage 3 kV (1 min, 50 Hz)
  • Voltage drop: 3%
  • Reduction of current harmonics generated by load, resulting in energy consumption reduction and power factor improvement
  • Reduction of the crest factor of the current wave, extending the lifetime of the equipment and avoiding breakdowns
  • Attenuation of microcuts in the supply voltage generated by power converters, causing malfuntioning of computers, PLC’s and other sensitive equipment

Copyright: Images and Specifications are property of POLYLUX, S.L
Please contact sales@comlec.com for assistance