- The ultimate transformer design with the best of the resin technology
- Available with different output voltages
- Transformer housing of Polymer of latest technology, non-flammable V-0 according to UL94 (up to 1000VA)
- Parts with risk of electrical contact are not accessible by the user
- Advantages of using resin:
- Protection against corrosive environments
- Suitable for elevated vibration levels
- No damage of wire isolation due to current peaks
- Reduction of noise and internal vibrations
PRODUCTS IN THIS FAMILY
If you need more information you can contact us.
Reference | Description | Rating | Input voltage | Output voltage | ||
---|---|---|---|---|---|---|
QB25 | Single phase resin filled control and safety transformer | 25 VA | 230/400 V | 12/24 V | ||
QB40 | Single phase resin filled control and safety transformer | 40 VA | 230/400 V | 12/24 V | ||
QB63 | Single phase resin filled control and safety transformer | 63 VA | 230/400 V | 12/24 V | ||
QB100 | Single phase resin filled control and safety transformer | 100 VA | 230/400 V | 12/24 V | ||
QB160 | Single phase resin filled control and safety transformer | 160 VA | 230/400/460 V | 12/24 V | ||
QB200 | Single phase resin filled control and safety transformer | 200 VA | 230/400/460 V | 12/24 V | ||
QB250 | Single phase resin filled control and safety transformer | 250 VA | 230/400/460 V | 12/24 V | ||
QB315 | Single phase resin filled control and safety transformer | 315 VA | 230/400/460 V | 12/24 V | ||
QB400 | Single phase resin filled control and safety transformer | 400 VA | 230/400/460 V | 12/24 V | ||
QB500 | Single phase resin filled control and safety transformer | 500 VA | 230/400/460 V | 12/24 V | ||
QC25 | Single phase resin filled control and safety transformer | 25 VA | 230/400 V | 24/48 V | ||
QC40 | Single phase resin filled control and safety transformer | 40 VA | 230/400 V | 24/48 V | ||
QC63 | Single phase resin filled control and safety transformer | 63 VA | 230/400 V | 24/48 V | ||
QC100 | Single phase resin filled control and safety transformer | 100 VA | 230/400 V | 24/48 V | ||
QC160 | Single phase resin filled control and safety transformer | 160 VA | 230/400/460 V | 24/48 V | ||
QC200 | Single phase resin filled control and safety transformer | 200 VA | 230/400/460 V | 24/48 V | ||
QC250 | Single phase resin filled control and safety transformer | 250 VA | 230/400/460 V | 24/48 V | ||
QC315 | Single phase resin filled control and safety transformer | 315 VA | 230/400/460 V | 24/48 V | ||
QC400 | Single phase resin filled control and safety transformer | 400 VA | 230/400/460 V | 24/48 V | ||
QC500 | Single phase resin filled control and safety transformer | 500 VA | 230/400/460 V | 24/48 V | ||
QC630 | Single phase resin filled control and safety transformer | 630 VA | 230/400/460 V | 24/48 V | ||
QC800 | Single phase resin filled control and safety transformer | 800 VA | 230/400/460 V | 24/48 V | ||
QC1000 | Single phase resin filled control and safety transformer | 1000 VA | 230/400/460 V | 24/48 V | ||
QC1250 | Single phase resin type control and safety transformer | 1250 VA | 230/400/460 V | 24/48 V | ||
QC1600 | Single phase resin type control and safety transformer | 1600 VA | 230/400/460 V | 24/48 V | ||
QC2000 | Single phase resin type control and safety transformer | 2000 VA | 230/400/460 V | 24/48 V | ||
QD25 | Single phase resin filled isolation transformer | 25 VA | 230/400 V | 115/230 V | ||
QD40 | Single phase resin filled isolation transformer | 40 VA | 230/400 V | 115/230 V | ||
QD63 | Single phase resin filled isolation transformer | 63 VA | 230/400 V | 115/230 V | ||
QD100 | Single phase resin filled isolation transformer | 100 VA | 230/400 V | 115/230 V | ||
QD160 | Single phase resin filled isolation transformer | 160 VA | 230/400/460 V | 115/230 V | ||
QD200 | Single phase resin filled isolation transformer | 200 VA | 230/400/460 V | 115/230 V | ||
QD250 | Single phase resin filled isolation transformer | 250 VA | 230/400/460 V | 115/230 V | ||
QD315 | Single phase resin filled isolation transformer | 315 VA | 230/400/460 V | 115/230 V | ||
QD400 | Single phase resin filled isolation transformer | 400 VA | 230/400/460 V | 115/230 V | ||
QD500 | Single phase resin filled isolation transformer | 500 VA | 230/400/460 V | 115/230 V | ||
QD630 | Single phase resin filled isolation transformer | 630 VA | 230/400/460 V | 115/230 V | ||
QD800 | Single phase resin filled isolation transformer | 800 VA | 230/400/460 V | 115/230 V | ||
QD1000 | Single phase resin filled isolation transformer | 1000 VA | 230/400/460 V | 115/230 V | ||
QD1250 | Single phase resin filled isolation transformer | 1250 VA | 230/400/460 V | 115/230 V | ||
QD1600 | Single phase resin type isolation transformer | 1600 VA | 230/400/460 V | 115/230 V | ||
QD2000 | Single phase resin type isolation transformer | 2000 VA | 230/400/460 V | 115/230 V | ||
QD2500 | Single phase resin type isolation transformer | 2500 VA | 230/400/460 V | 115/230 V |
DIMENSIONS AND WEIGHTS
Reference | Description | Rating | Dimensions mm | Weight kg | Fig | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | B | C | D | E | Ø | ||||||
QB25 | Single phase resin filled control and safety transformer | 25 VA | 69 | 92 | 80 | 79 | 45 | 5 | 0.79 | 1 | |
QB40 | Single phase resin filled control and safety transformer | 40 VA | 69 | 92 | 80 | 79 | 45 | 5 | 0.94 | 1 | |
QB63 | Single phase resin filled control and safety transformer | 63 VA | 84 | 101 | 98 | 88 | 55 | 5 | 1.4 | 1 | |
QB100 | Single phase resin filled control and safety transformer | 100 VA | 84 | 101 | 98 | 88 | 55 | 5 | 1.8 | 1 | |
QB160 | Single phase resin filled control and safety transformer | 160 VA | 106 | 123 | 118 | 110 | 74 | 5 | 2.9 | 1 | |
QB200 | Single phase resin filled control and safety transformer | 200 VA | 106 | 123 | 118 | 110 | 74 | 5 | 3.4 | 1 | |
QB250 | Single phase resin filled control and safety transformer | 250 VA | 106 | 123 | 118 | 110 | 74 | 5 | 4 | 1 | |
QB315 | Single phase resin filled control and safety transformer | 315 VA | 118 | 138 | 131 | 121 | 88 | 6 | 5 | 1 | |
QB400 | Single phase resin filled control and safety transformer | 400 VA | 118 | 138 | 131 | 121 | 88 | 6 | 5.5 | 1 | |
QB500 | Single phase resin filled control and safety transformer | 500 VA | 136 | 162 | 156 | 145 | 104 | 6 | 8.7 | 1 | |
QC25 | Single phase resin filled control and safety transformer | 25 VA | 69 | 92 | 80 | 79 | 45 | 5 | 0.79 | 1 | |
QC40 | Single phase resin filled control and safety transformer | 40 VA | 69 | 92 | 80 | 79 | 45 | 5 | 0.94 | 1 | |
QC63 | Single phase resin filled control and safety transformer | 63 VA | 84 | 101 | 98 | 88 | 55 | 5 | 1.4 | 1 | |
QC100 | Single phase resin filled control and safety transformer | 100 VA | 84 | 101 | 98 | 88 | 55 | 5 | 1.8 | 1 | |
QC160 | Single phase resin filled control and safety transformer | 160 VA | 106 | 123 | 118 | 110 | 74 | 5 | 2.9 | 1 | |
QC200 | Single phase resin filled control and safety transformer | 200 VA | 106 | 123 | 118 | 110 | 74 | 5 | 3.4 | 1 | |
QC250 | Single phase resin filled control and safety transformer | 250 VA | 106 | 123 | 118 | 110 | 74 | 5 | 4 | 1 | |
QC315 | Single phase resin filled control and safety transformer | 315 VA | 118 | 138 | 131 | 121 | 88 | 6 | 5 | 1 | |
QC400 | Single phase resin filled control and safety transformer | 400 VA | 118 | 138 | 131 | 121 | 88 | 6 | 5.5 | 1 | |
QC500 | Single phase resin filled control and safety transformer | 500 VA | 136 | 162 | 156 | 145 | 104 | 6 | 8.7 | 1 | |
QC630 | Single phase resin filled control and safety transformer | 630 VA | 136 | 162 | 156 | 145 | 104 | 6 | 8.8 | 1 | |
QC800 | Single phase resin filled control and safety transformer | 800 VA | 136 | 162 | 156 | 145 | 104 | 6 | 9.7 | 1 | |
QC1000 | Single phase resin filled control and safety transformer | 1000 VA | 136 | 162 | 180 | 145 | 104 | 6 | 10.5 | 1 | |
QC1250 | Single phase resin type control and safety transformer | 1250 VA | 233 | 241 | 244 | 219 | 175 | 7 | 25.6 | 2 | |
QC1600 | Single phase resin type control and safety transformer | 1600 VA | 233 | 241 | 274 | 219 | 175 | 7 | 30 | 2 | |
QC2000 | Single phase resin type control and safety transformer | 2000 VA | 233 | 241 | 314 | 219 | 175 | 7 | 37.6 | 2 | |
QD25 | Single phase resin filled isolation transformer | 25 VA | 69 | 92 | 80 | 79 | 45 | 5 | 0.8 | 1 | |
QD40 | Single phase resin filled isolation transformer | 40 VA | 69 | 92 | 80 | 79 | 45 | 5 | 0.94 | 1 | |
QD63 | Single phase resin filled isolation transformer | 63 VA | 84 | 101 | 98 | 88 | 55 | 5 | 1.4 | 1 | |
QD100 | Single phase resin filled isolation transformer | 100 VA | 84 | 101 | 98 | 88 | 55 | 5 | 1.8 | 1 | |
QD160 | Single phase resin filled isolation transformer | 160 VA | 106 | 123 | 118 | 110 | 74 | 5 | 2.9 | 1 | |
QD200 | Single phase resin filled isolation transformer | 200 VA | 106 | 123 | 118 | 110 | 74 | 5 | 3.4 | 1 | |
QD250 | Single phase resin filled isolation transformer | 250 VA | 106 | 123 | 118 | 110 | 74 | 5 | 4 | 1 | |
QD315 | Single phase resin filled isolation transformer | 315 VA | 118 | 138 | 131 | 121 | 88 | 6 | 5 | 1 | |
QD400 | Single phase resin filled isolation transformer | 400 VA | 118 | 138 | 131 | 121 | 88 | 6 | 5.5 | 1 | |
QD500 | Single phase resin filled isolation transformer | 500 VA | 136 | 162 | 156 | 145 | 104 | 6 | 8.7 | 1 | |
QD630 | Single phase resin filled isolation transformer | 630 VA | 136 | 162 | 156 | 145 | 104 | 6 | 8.8 | 1 | |
QD800 | Single phase resin filled isolation transformer | 800 VA | 136 | 162 | 156 | 145 | 104 | 6 | 9.7 | 1 | |
QD1000 | Single phase resin filled isolation transformer | 1000 VA | 136 | 162 | 180 | 145 | 104 | 6 | 10.5 | 1 | |
QD1250 | Single phase resin type isolation transformer | 1250 VA | 233 | 241 | 244 | 219 | 175 | 7 | 25.6 | 2 | |
QD1600 | Single phase resin type isolation transformer | 1600 VA | 233 | 241 | 274 | 219 | 175 | 7 | 30 | 2 | |
QD2000 | Single phase resin type isolation transformer | 2000 VA | 233 | 241 | 314 | 219 | 175 | 7 | 37.6 | 2 | |
QD2500 | Single phase resin type isolation transformer | 2500 VA | 233 | 241 | 314 | 219 | 175 | 7 | 38.5 | 2 |
TECHNICAL CHARACTERISTICS
Isolation | Class B – 130º C |
Winding | Class HC – 200ºC |
Cover | Polymer of latest technology, non-flammable V-0 according to UL94 (up to 1000VA)Cast resin (as from 1250VA) |
Frequency | 50-60 Hz |
Protection degree | IP-20 |
Includes | LED indicator |
Mounting | By screws (for all ratings)DIN Rail mounting (for ratings up to 100 VA) |
Standards | IEC/EN/UNE-EN 61558 CE |
Protection | Class I and Class II (selectable up to 1000VA) |
Voltage selection | By metal bridges, included |
Test voltage | 4,6 kV (1 min, 50 Hz) between primary and secondary3,2 kV (1 min, 50 Hz) between primary and earth2,5 kV (1 min, 50 Hz) between secondary and earth |
Remarks | Resin type and tropicalised |
- The only transformer that can be set to Class I and Class II (up to 1000VA)
- Signal LED