IP – SINGLE PHASE CAST RESIN TRANSFORMER IP-54

For application in locations with risk of direct contact with water or other liquids

Series: IP              
IP - Single phase cast resin transformer IP-54
If you need more information you can contact us at sales@comlec.com
  • Advantages of cast resin technique:
    • Protection against corrosive environments
    • Suitable for elevated vibration levels
    • No damange of wire isolation due to current peaks
    • Reduction of noise and internal vibrations

PRODUCTS IN THIS FAMILY

Reference Description Rating Input voltage Output voltage
IPB100 Single phase cast resin transformer IP-54 100 VA 230/400 V 12/24 V
IPB200 Single phase cast resin transformer IP-54 200 VA 230/400/460 V 12/24 V
IPB315 Single phase cast resin transformer IP-54 315 VA 230/400/460 V 12/24 V
IPB500 Single phase cast resin transformer IP-54 500 VA 230/400/460 V 12/24 V
IPB630 Single phase cast resin transformer IP-54 630 VA 230/400/460 V 12/24 V
IPB1000 Single phase cast resin transformer IP-54 1000 VA 230/400/460 V 12/24 V
IPB1600 Single phase cast resin transformer IP-54 1600 VA 230/400/460 V 12/24 V
IPB2000 Single phase cast resin transformer IP-54 2000 VA 230/400/460 V 12/24 V
IPD100 Single phase cast resin transformer IP-54 100 VA 230/400 V 115/230 V
IPD200 Single phase cast resin transformer IP-54 200 VA 230/400/460 V 115/230 V
IPD315 Single phase cast resin transformer IP-54 315 VA 230/400/460 V 115/230 V
IPD500 Single phase cast resin transformer IP-54 500 VA 230/400/460 V 115/230 V
IPD630 Single phase cast resin transformer IP-54 630 VA 230/400/460 V 115/230 V
IPD1000 Single phase cast resin transformer IP-54 1000 VA 230/400/460 V 115/230 V
IPD1600 Single phase cast resin transformer IP-54 1600 VA 230/400/460 V 115/230 V
IPD2000 Single phase cast resin transformer IP-54 2000 VA 230/400/460 V 115/230 V

DIMENSIONS AND WEIGHTS

Reference Rating Dimensions mm Weight kg Fig
A B C D E Ø
IPB100 100 VA 126 145 170 125 102 7 5.6
IPB200 200 VA 150 165 190 145 125 7 7.3
IPB315 315 VA 150 165 210 145 125 7 9.2
IPB500 500 VA 195 198 220 178 173 7 11.9
IPB630 630 VA 195 198 260 178 173 7 19.1
IPB1000 1000 VA 240 235 260 212 218 7 30.3
IPB1600 1600 VA 260 272 310 250 238 7 47.3
IPB2000 2000 VA 260 272 330 250 238 7 53
IPD100 100 VA 126 145 170 125 102 7 5.6
IPD200 200 VA 150 165 190 145 125 7 7.3
IPD315 315 VA 150 165 210 145 125 7 9.2
IPD500 500 VA 195 198 220 178 173 7 11.9
IPD630 630 VA 195 198 260 178 173 7 19.1
IPD1000 1000 VA 240 235 260 212 218 7 30.3
IPD1600 1600 VA 260 272 310 250 238 7 41.9
IPD2000 2000 VA 260 272 330 250 238 7 49.2

TECHNICAL CHARACTERISTICS

Isolation Class B – 130º C
Winding Class HC – 200ºC
Cover Completely cast resin
Frequency 50-60 Hz
Protection degree IP-54
Standards IEC/EN/UNE-EN 61558 CE
Voltage selection By metal bridges, included
Test voltage 4,6 kV (1 min, 50 Hz) between primary and secondary
3,2 kV (1 min, 50 Hz) between primary and earth
2,5 kV (1 min, 50 Hz) between secondary and earth
copyright: Polylux Product images and specifications are property of POLYLUX, SL
Contact us at sales@comlec.com