Input 230 V · Output 230 V.
Series: TKE
If you need more information you can contact us at sales@comlec.com
- Advantages of cast resin technique:
- Protection against corrosive environments
- Suitable for elevated vibration levels
- No damange of wire isolation due to current peaks
- Reduction of noise and internal vibrations
PRODUCTS IN THIS FAMILY
Reference | Description | Rating | Input voltage | Output voltage | ||
---|---|---|---|---|---|---|
TKE3.15 | Single phase cast resin isolating transformer | 3,15 kVA | 230 V | 230 V | ||
TKE4 | Single phase cast resin isolating transformer | 4 kVA | 230 V | 230 V | ||
TKE5 | Single phase cast resin isolating transformer | 5 kVA | 230 V | 230 V | ||
TKE6.3 | Single phase cast resin isolating transformer | 6,3 kVA | 230 V | 230 V | ||
TKE8 | Single phase cast resin isolating transformer | 8 kVA | 230 V | 230 V | ||
TKE10 | Single phase cast resin isolating transformer | 10 kVA | 230 V | 230 V | ||
TKE12.5 | Single phase cast resin isolating transformer | 12,5 kVA | 230 V | 230 V | ||
TKE16 | Single phase cast resin isolating transformer | 16 kVA | 230 V | 230 V | ||
TKE20 | Single phase cast resin isolating transformer | 20 kVA | 230 V | 230 V | ||
TKE25 | Single phase cast resin isolating transformer | 25 kVA | 230 V | 230 V | ||
TKE31.5 | Single phase cast resin isolating transformer | 31,5 kVA | 230 V | 230 V | ||
TKE40 | Single phase cast resin isolating transformer | 40 kVA | 230 V | 230 V | ||
TKE50 | Single phase cast resin isolating transformer | 50 kVA | 230 V | 230 V |
DIMENSIONS AND WEIGHTS
Reference | Rating | Dimensions mm | Weight kg | Fig | ||||||
---|---|---|---|---|---|---|---|---|---|---|
A | B | C | D | E | Ø | |||||
TKE3.15 | 3,15 kVA | 245 | 245 | 255 | 138 | 210 | 11 | 34 | 1 | |
TKE4 | 4 kVA | 295 | 292 | 305 | 118 | 260 | 11 | 44 | 1 | |
TKE5 | 5 kVA | 295 | 292 | 305 | 138 | 260 | 11 | 53 | 1 | |
TKE6.3 | 6,3 kVA | 340 | 320 | 355 | 142 | 310 | 11 | 74 | 1 | |
TKE8 | 8 kVA | 340 | 320 | 355 | 162 | 310 | 11 | 89 | 1 | |
TKE10 | 10 kVA | 390 | 360 | 405 | 150 | 360 | 11 | 93 | 2 | |
TKE12.5 | 12,5 kVA | 390 | 360 | 405 | 150 | 360 | 11 | 101 | 2 | |
TKE16 | 16 kVA | 390 | 360 | 405 | 170 | 360 | 11 | 112 | 2 | |
TKE20 | 20 kVA | 390 | 360 | 405 | 190 | 360 | 11 | 134 | 2 | |
TKE25 | 25 kVA | 390 | 380 | 405 | 210 | 360 | 11 | 161 | 2 | |
TKE31.5 | 31,5 kVA | 440 | 385 | 560 | 180 | 250 | 11 | 185 | 2 | |
TKE40 | 40 kVA | 440 | 405 | 560 | 200 | 250 | 11 | 213 | 2 | |
TKE50 | 50 kVA | 440 | 425 | 560 | 220 | 250 | 11 | 260 | 2 |
TECHNICAL CHARACTERISTICS
Isolation | Class F – 155ºC up to 8 kVA Class H – 180ºC as from 10 kVA |
Winding | Class HC – 200ºC |
Cover | Cast resin |
Frequency | 50-60 Hz |
Protection degree | IP-20 up to 8 kVA / IP-00 as from 10 kVA |
Includes | Thermal protection against over temperature (up to 8 kVA) Lifting eyebolts |
Standards | IEC/EN/UNE-EN 61558, CE up to 31,5 kVA IEC/EN/UNE-EN 60076, CE as from 40 kVA |
Cooling | AN |
Ambient temperature | 30ºC |
Test voltage | 3 kV (1 min, 50 Hz) |